Cleaning and dust removal of electrical cabinets
Conductive dust, grease and contamination in your electrical cabinets and switchboards cause breakdowns, short circuits and fire risks. Dry ice cleaning removes them with no water and no chemicals, possible while live, without taking your installations out of service.
A dirty cabinet, a real risk
- Conductive dust creates a risk of short circuits and arc flashes
- Contamination of contactors and relays causes costly nuisance failures
- Dust build-up reduces heat dissipation, with a risk of overheating
- Compressed-air cleaning moves dust around without removing it
- Switching the installation off for cleaning: costly production downtime
A clean cabinet, a maintained installation
- Complete removal of dust, grease and contamination: fully removed, not moved elsewhere
- Dry, non-conductive process; live work only in the presence of a BA4/BA5-qualified operator from your team
- Zero water, no risk of moisture-related short circuits
- Precision cleaning in the most complex areas: contactors, relays, busbars
- Job report for your electrical maintenance log and your audits
What we clean in your installations
HV/LV distribution cabinets
Cleaning of high and low voltage cabinets in substations, transformer stations and industrial buildings.
Industrial switchboards
Cleaning of control panels, control boxes and PLC cabinets on production lines.
Telecom cabinets
Cleaning of server racks, network cabinets and telecom equipment in server rooms and data centers.
Machine control boxes
Cleaning of electrical boxes built into production machines, without dismantling.
Transformers & UPS units
Cleaning of transformers, UPS units and power conversion equipment fouled by conductive dust.
Solar inverters
Cleaning of inverters and junction boxes in solar installations, alongside panel cleaning.
How a job works
Technical discussion
You describe the installation, the fouling and the access constraints, with photos if possible. Together we define the isolation arrangements.
Preparation with your electrical manager
Risk analysis under the Belgian electrical regulations (RGIE), work permit and isolation according to your procedures. A safety zone is set up around the cabinet.
Dry ice cleaning
Pressure adjusted to the components, with a prior test on the most delicate parts. Dust is removed, not moved around.
Inspection and report
Visual check, before and after photos, job report for your maintenance log and your audits.
Isolated or live: our rule
Dry ice is not conductive and the process is completely dry: it brings no water or moisture into the cabinet. This does not replace a risk analysis. We carry it out with your electrical manager before every job.
Isolated
This is our standard way of working. A partial shutdown is often enough, which limits downtime to the circuits concerned.
Live
Only in the presence of a BA4/BA5-qualified operator from your team, as our technicians do not hold this qualification.
In practice
- Duration
- Usually 1 to 3 hours per cabinet, depending on its size and how dirty it is. A batch of cabinets or a complete substation is planned over one or more days.
- Indicative price
- From €200 to €500 excl. VAT for a small job of 1 to 2 hours. Beyond that, the price depends on the number of cabinets and access. See the price ranges. Free quote, reply within 6 working hours.
- What you avoid
- Dismantling components, solvents, moisture, and dust simply blown elsewhere by compressed air.
- Safety
- Technicians trained and individually VCA-certified. Work in ATEX zones is possible after the zone has been declassified by your site.
- Service area
- All of Belgium (Wallonia, Brussels, Flanders) and the Grand Duchy of Luxembourg, from Namur.
Electrical cabinet cleaning
Free quote within 6h
Describe your installation and your constraints. An Icetec expert will reply with a suitable solution, with no obligation.